ASPEED AST2400/AST2500 PWM and Fan Tacho controller device driver
|
||
|
|
||
|
The ASPEED PWM controller can support upto 8 PWM outputs. The ASPEED Fan Tacho
|
||
|
controller can support upto 16 Fan tachometer inputs.
|
||
|
|
||
|
There can be upto 8 fans supported. Each fan can have one PWM output and
|
||
|
one/two Fan tach inputs.
|
||
|
|
||
|
Required properties for pwm-tacho node:
|
||
|
- #address-cells : should be 1.
|
||
|
|
||
|
- #size-cells : should be 1.
|
||
|
|
||
|
- #cooling-cells: should be 2.
|
||
|
|
||
|
- reg : address and length of the register set for the device.
|
||
|
|
||
|
- pinctrl-names : a pinctrl state named "default" must be defined.
|
||
|
|
||
|
- pinctrl-0 : phandle referencing pin configuration of the PWM ports.
|
||
|
|
||
|
- compatible : should be "aspeed,ast2400-pwm-tacho" for AST2400 and
|
||
|
"aspeed,ast2500-pwm-tacho" for AST2500.
|
||
|
|
||
|
- clocks : phandle to clock provider with the clock number in the second cell
|
||
|
|
||
|
- resets : phandle to reset controller with the reset number in the second cell
|
||
|
|
||
|
fan subnode format:
|
||
|
===================
|
||
|
Under fan subnode there can upto 8 child nodes, with each child node
|
||
|
representing a fan. If there are 8 fans each fan can have one PWM port and
|
||
|
one/two Fan tach inputs.
|
||
|
For PWM port can be configured cooling-levels to create cooling device.
|
||
|
Cooling device could be bound to a thermal zone for the thermal control.
|
||
|
|
||
|
Required properties for each child node:
|
||
|
- reg : should specify PWM source port.
|
||
|
integer value in the range 0 to 7 with 0 indicating PWM port A and
|
||
|
7 indicating PWM port H.
|
||
|
|
||
|
- cooling-levels: PWM duty cycle values in a range from 0 to 255
|
||
|
which correspond to thermal cooling states.
|
||
|
|
||
|
- aspeed,fan-tach-ch : should specify the Fan tach input channel.
|
||
|
integer value in the range 0 through 15, with 0 indicating
|
||
|
Fan tach channel 0 and 15 indicating Fan tach channel 15.
|
||
|
Atleast one Fan tach input channel is required.
|
||
|
|
||
|
Examples:
|
||
|
|
||
|
pwm_tacho: pwmtachocontroller@1e786000 {
|
||
|
#address-cells = <1>;
|
||
|
#size-cells = <1>;
|
||
|
#cooling-cells = <2>;
|
||
|
reg = <0x1E786000 0x1000>;
|
||
|
compatible = "aspeed,ast2500-pwm-tacho";
|
||
|
clocks = <&syscon ASPEED_CLK_APB>;
|
||
|
resets = <&syscon ASPEED_RESET_PWM>;
|
||
|
pinctrl-names = "default";
|
||
|
pinctrl-0 = <&pinctrl_pwm0_default &pinctrl_pwm1_default>;
|
||
|
|
||
|
fan@0 {
|
||
|
reg = <0x00>;
|
||
|
cooling-levels = /bits/ 8 <125 151 177 203 229 255>;
|
||
|
aspeed,fan-tach-ch = /bits/ 8 <0x00>;
|
||
|
};
|
||
|
|
||
|
fan@1 {
|
||
|
reg = <0x01>;
|
||
|
aspeed,fan-tach-ch = /bits/ 8 <0x01 0x02>;
|
||
|
};
|
||
|
};
|