// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* Copyright (C) 2017 SiFive
|
|
*/
|
|
|
|
#include <linux/of.h>
|
|
#include <asm/cacheflush.h>
|
|
|
|
#ifdef CONFIG_SMP
|
|
|
|
#include <asm/sbi.h>
|
|
|
|
static void ipi_remote_fence_i(void *info)
|
|
{
|
|
return local_flush_icache_all();
|
|
}
|
|
|
|
void flush_icache_all(void)
|
|
{
|
|
local_flush_icache_all();
|
|
|
|
if (IS_ENABLED(CONFIG_RISCV_SBI) && !riscv_use_ipi_for_rfence())
|
|
sbi_remote_fence_i(NULL);
|
|
else
|
|
on_each_cpu(ipi_remote_fence_i, NULL, 1);
|
|
}
|
|
EXPORT_SYMBOL(flush_icache_all);
|
|
|
|
/*
|
|
* Performs an icache flush for the given MM context. RISC-V has no direct
|
|
* mechanism for instruction cache shoot downs, so instead we send an IPI that
|
|
* informs the remote harts they need to flush their local instruction caches.
|
|
* To avoid pathologically slow behavior in a common case (a bunch of
|
|
* single-hart processes on a many-hart machine, ie 'make -j') we avoid the
|
|
* IPIs for harts that are not currently executing a MM context and instead
|
|
* schedule a deferred local instruction cache flush to be performed before
|
|
* execution resumes on each hart.
|
|
*/
|
|
void flush_icache_mm(struct mm_struct *mm, bool local)
|
|
{
|
|
unsigned int cpu;
|
|
cpumask_t others, *mask;
|
|
|
|
preempt_disable();
|
|
|
|
/* Mark every hart's icache as needing a flush for this MM. */
|
|
mask = &mm->context.icache_stale_mask;
|
|
cpumask_setall(mask);
|
|
/* Flush this hart's I$ now, and mark it as flushed. */
|
|
cpu = smp_processor_id();
|
|
cpumask_clear_cpu(cpu, mask);
|
|
local_flush_icache_all();
|
|
|
|
/*
|
|
* Flush the I$ of other harts concurrently executing, and mark them as
|
|
* flushed.
|
|
*/
|
|
cpumask_andnot(&others, mm_cpumask(mm), cpumask_of(cpu));
|
|
local |= cpumask_empty(&others);
|
|
if (mm == current->active_mm && local) {
|
|
/*
|
|
* It's assumed that at least one strongly ordered operation is
|
|
* performed on this hart between setting a hart's cpumask bit
|
|
* and scheduling this MM context on that hart. Sending an SBI
|
|
* remote message will do this, but in the case where no
|
|
* messages are sent we still need to order this hart's writes
|
|
* with flush_icache_deferred().
|
|
*/
|
|
smp_mb();
|
|
} else if (IS_ENABLED(CONFIG_RISCV_SBI) &&
|
|
!riscv_use_ipi_for_rfence()) {
|
|
sbi_remote_fence_i(&others);
|
|
} else {
|
|
on_each_cpu_mask(&others, ipi_remote_fence_i, NULL, 1);
|
|
}
|
|
|
|
preempt_enable();
|
|
}
|
|
|
|
#endif /* CONFIG_SMP */
|
|
|
|
#ifdef CONFIG_MMU
|
|
void flush_icache_pte(pte_t pte)
|
|
{
|
|
struct page *page = pte_page(pte);
|
|
|
|
/*
|
|
* HugeTLB pages are always fully mapped, so only setting head page's
|
|
* PG_dcache_clean flag is enough.
|
|
*/
|
|
if (PageHuge(page))
|
|
page = compound_head(page);
|
|
|
|
if (!test_bit(PG_dcache_clean, &page->flags)) {
|
|
flush_icache_all();
|
|
set_bit(PG_dcache_clean, &page->flags);
|
|
}
|
|
}
|
|
#endif /* CONFIG_MMU */
|
|
|
|
unsigned int riscv_cbom_block_size;
|
|
EXPORT_SYMBOL_GPL(riscv_cbom_block_size);
|
|
|
|
unsigned int riscv_cboz_block_size;
|
|
EXPORT_SYMBOL_GPL(riscv_cboz_block_size);
|
|
|
|
static void __init cbo_get_block_size(struct device_node *node,
|
|
const char *name, u32 *block_size,
|
|
unsigned long *first_hartid)
|
|
{
|
|
unsigned long hartid;
|
|
u32 val;
|
|
|
|
if (riscv_of_processor_hartid(node, &hartid))
|
|
return;
|
|
|
|
if (of_property_read_u32(node, name, &val))
|
|
return;
|
|
|
|
if (!*block_size) {
|
|
*block_size = val;
|
|
*first_hartid = hartid;
|
|
} else if (*block_size != val) {
|
|
pr_warn("%s mismatched between harts %lu and %lu\n",
|
|
name, *first_hartid, hartid);
|
|
}
|
|
}
|
|
|
|
void __init riscv_init_cbo_blocksizes(void)
|
|
{
|
|
unsigned long cbom_hartid, cboz_hartid;
|
|
u32 cbom_block_size = 0, cboz_block_size = 0;
|
|
struct device_node *node;
|
|
|
|
for_each_of_cpu_node(node) {
|
|
/* set block-size for cbom and/or cboz extension if available */
|
|
cbo_get_block_size(node, "riscv,cbom-block-size",
|
|
&cbom_block_size, &cbom_hartid);
|
|
cbo_get_block_size(node, "riscv,cboz-block-size",
|
|
&cboz_block_size, &cboz_hartid);
|
|
}
|
|
|
|
if (cbom_block_size)
|
|
riscv_cbom_block_size = cbom_block_size;
|
|
|
|
if (cboz_block_size)
|
|
riscv_cboz_block_size = cboz_block_size;
|
|
}
|