// SPDX-License-Identifier: GPL-2.0+
|
|
/*
|
|
* Hardware monitoring driver for Vicor PLI1209BC Digital Supervisor
|
|
*
|
|
* Copyright (c) 2022 9elements GmbH
|
|
*/
|
|
|
|
#include <linux/i2c.h>
|
|
#include <linux/module.h>
|
|
#include <linux/pmbus.h>
|
|
#include <linux/regulator/driver.h>
|
|
#include "pmbus.h"
|
|
|
|
/*
|
|
* The capability command is only supported at page 0. Probing the device while
|
|
* the page register is set to 1 will falsely enable PEC support. Disable
|
|
* capability probing accordingly, since the PLI1209BC does not have any
|
|
* additional capabilities.
|
|
*/
|
|
static struct pmbus_platform_data pli1209bc_plat_data = {
|
|
.flags = PMBUS_NO_CAPABILITY,
|
|
};
|
|
|
|
static int pli1209bc_read_word_data(struct i2c_client *client, int page,
|
|
int phase, int reg)
|
|
{
|
|
int data;
|
|
|
|
switch (reg) {
|
|
/* PMBUS_READ_POUT uses a direct format with R=0 */
|
|
case PMBUS_READ_POUT:
|
|
data = pmbus_read_word_data(client, page, phase, reg);
|
|
if (data < 0)
|
|
return data;
|
|
data = sign_extend32(data, 15) * 10;
|
|
return clamp_val(data, -32768, 32767) & 0xffff;
|
|
/*
|
|
* PMBUS_READ_VOUT and PMBUS_READ_TEMPERATURE_1 return invalid data
|
|
* when the BCM is turned off. Since it is not possible to return
|
|
* ENODATA error, return zero instead.
|
|
*/
|
|
case PMBUS_READ_VOUT:
|
|
case PMBUS_READ_TEMPERATURE_1:
|
|
data = pmbus_read_word_data(client, page, phase,
|
|
PMBUS_STATUS_WORD);
|
|
if (data < 0)
|
|
return data;
|
|
if (data & PB_STATUS_POWER_GOOD_N)
|
|
return 0;
|
|
return pmbus_read_word_data(client, page, phase, reg);
|
|
default:
|
|
return -ENODATA;
|
|
}
|
|
}
|
|
|
|
#if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR)
|
|
static const struct regulator_desc pli1209bc_reg_desc = {
|
|
.name = "vout2",
|
|
.id = 1,
|
|
.of_match = of_match_ptr("vout2"),
|
|
.regulators_node = of_match_ptr("regulators"),
|
|
.ops = &pmbus_regulator_ops,
|
|
.type = REGULATOR_VOLTAGE,
|
|
.owner = THIS_MODULE,
|
|
};
|
|
#endif
|
|
|
|
static struct pmbus_driver_info pli1209bc_info = {
|
|
.pages = 2,
|
|
.format[PSC_VOLTAGE_IN] = direct,
|
|
.format[PSC_VOLTAGE_OUT] = direct,
|
|
.format[PSC_CURRENT_IN] = direct,
|
|
.format[PSC_CURRENT_OUT] = direct,
|
|
.format[PSC_POWER] = direct,
|
|
.format[PSC_TEMPERATURE] = direct,
|
|
.m[PSC_VOLTAGE_IN] = 1,
|
|
.b[PSC_VOLTAGE_IN] = 0,
|
|
.R[PSC_VOLTAGE_IN] = 1,
|
|
.m[PSC_VOLTAGE_OUT] = 1,
|
|
.b[PSC_VOLTAGE_OUT] = 0,
|
|
.R[PSC_VOLTAGE_OUT] = 1,
|
|
.m[PSC_CURRENT_IN] = 1,
|
|
.b[PSC_CURRENT_IN] = 0,
|
|
.R[PSC_CURRENT_IN] = 3,
|
|
.m[PSC_CURRENT_OUT] = 1,
|
|
.b[PSC_CURRENT_OUT] = 0,
|
|
.R[PSC_CURRENT_OUT] = 2,
|
|
.m[PSC_POWER] = 1,
|
|
.b[PSC_POWER] = 0,
|
|
.R[PSC_POWER] = 1,
|
|
.m[PSC_TEMPERATURE] = 1,
|
|
.b[PSC_TEMPERATURE] = 0,
|
|
.R[PSC_TEMPERATURE] = 0,
|
|
/*
|
|
* Page 0 sums up all attributes except voltage readings.
|
|
* The pli1209 digital supervisor only contains a single BCM, making
|
|
* page 0 redundant.
|
|
*/
|
|
.func[1] = PMBUS_HAVE_VIN | PMBUS_HAVE_VOUT
|
|
| PMBUS_HAVE_IIN | PMBUS_HAVE_IOUT
|
|
| PMBUS_HAVE_PIN | PMBUS_HAVE_POUT
|
|
| PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP
|
|
| PMBUS_HAVE_STATUS_IOUT | PMBUS_HAVE_STATUS_INPUT,
|
|
.read_word_data = pli1209bc_read_word_data,
|
|
#if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR)
|
|
.num_regulators = 1,
|
|
.reg_desc = &pli1209bc_reg_desc,
|
|
#endif
|
|
};
|
|
|
|
static int pli1209bc_probe(struct i2c_client *client)
|
|
{
|
|
client->dev.platform_data = &pli1209bc_plat_data;
|
|
return pmbus_do_probe(client, &pli1209bc_info);
|
|
}
|
|
|
|
static const struct i2c_device_id pli1209bc_id[] = {
|
|
{"pli1209bc", 0},
|
|
{}
|
|
};
|
|
|
|
MODULE_DEVICE_TABLE(i2c, pli1209bc_id);
|
|
|
|
#ifdef CONFIG_OF
|
|
static const struct of_device_id pli1209bc_of_match[] = {
|
|
{ .compatible = "vicor,pli1209bc" },
|
|
{ },
|
|
};
|
|
MODULE_DEVICE_TABLE(of, pli1209bc_of_match);
|
|
#endif
|
|
|
|
static struct i2c_driver pli1209bc_driver = {
|
|
.driver = {
|
|
.name = "pli1209bc",
|
|
.of_match_table = of_match_ptr(pli1209bc_of_match),
|
|
},
|
|
.probe = pli1209bc_probe,
|
|
.id_table = pli1209bc_id,
|
|
};
|
|
|
|
module_i2c_driver(pli1209bc_driver);
|
|
|
|
MODULE_AUTHOR("Marcello Sylvester Bauer <sylv@sylv.io>");
|
|
MODULE_DESCRIPTION("PMBus driver for Vicor PLI1209BC");
|
|
MODULE_LICENSE("GPL");
|
|
MODULE_IMPORT_NS(PMBUS);
|