.. SPDX-License-Identifier: GPL-2.0
|
|
|
|
===============================================================
|
|
Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface
|
|
===============================================================
|
|
|
|
:Copyright: © 2022 Intel Corporation
|
|
|
|
:Author: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
|
|
|
|
Introduction
|
|
------------
|
|
|
|
Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform
|
|
level hardware/software solution for power and thermal management.
|
|
|
|
As a container for multiple power/thermal technologies, DPTF provides
|
|
a coordinated approach for different policies to effect the hardware
|
|
state of a system.
|
|
|
|
Since it is a platform level framework, this has several components.
|
|
Some parts of the technology is implemented in the firmware and uses
|
|
ACPI and PCI devices to expose various features for monitoring and
|
|
control. Linux has a set of kernel drivers exposing hardware interface
|
|
to user space. This allows user space thermal solutions like
|
|
"Linux Thermal Daemon" to read platform specific thermal and power
|
|
tables to deliver adequate performance while keeping the system under
|
|
thermal limits.
|
|
|
|
DPTF ACPI Drivers interface
|
|
----------------------------
|
|
|
|
:file:`/sys/bus/platform/devices/<N>/uuids`, where <N>
|
|
=INT3400|INTC1040|INTC1041|INTC10A0
|
|
|
|
``available_uuids`` (RO)
|
|
A set of UUIDs strings presenting available policies
|
|
which should be notified to the firmware when the
|
|
user space can support those policies.
|
|
|
|
UUID strings:
|
|
|
|
"42A441D6-AE6A-462b-A84B-4A8CE79027D3" : Passive 1
|
|
|
|
"3A95C389-E4B8-4629-A526-C52C88626BAE" : Active
|
|
|
|
"97C68AE7-15FA-499c-B8C9-5DA81D606E0A" : Critical
|
|
|
|
"63BE270F-1C11-48FD-A6F7-3AF253FF3E2D" : Adaptive performance
|
|
|
|
"5349962F-71E6-431D-9AE8-0A635B710AEE" : Emergency call
|
|
|
|
"9E04115A-AE87-4D1C-9500-0F3E340BFE75" : Passive 2
|
|
|
|
"F5A35014-C209-46A4-993A-EB56DE7530A1" : Power Boss
|
|
|
|
"6ED722A7-9240-48A5-B479-31EEF723D7CF" : Virtual Sensor
|
|
|
|
"16CAF1B7-DD38-40ED-B1C1-1B8A1913D531" : Cooling mode
|
|
|
|
"BE84BABF-C4D4-403D-B495-3128FD44dAC1" : HDC
|
|
|
|
``current_uuid`` (RW)
|
|
User space can write strings from available UUIDs, one at a
|
|
time.
|
|
|
|
:file:`/sys/bus/platform/devices/<N>/`, where <N>
|
|
=INT3400|INTC1040|INTC1041|INTC10A0
|
|
|
|
``imok`` (WO)
|
|
User space daemon write 1 to respond to firmware event
|
|
for sending keep alive notification. User space receives
|
|
THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when
|
|
firmware calls for user space to respond with imok ACPI
|
|
method.
|
|
|
|
``odvp*`` (RO)
|
|
Firmware thermal status variable values. Thermal tables
|
|
calls for different processing based on these variable
|
|
values.
|
|
|
|
``data_vault`` (RO)
|
|
Binary thermal table. Refer to
|
|
https:/github.com/intel/thermal_daemon for decoding
|
|
thermal table.
|
|
|
|
``production_mode`` (RO)
|
|
When different from zero, manufacturer locked thermal configuration
|
|
from further changes.
|
|
|
|
ACPI Thermal Relationship table interface
|
|
------------------------------------------
|
|
|
|
:file:`/dev/acpi_thermal_rel`
|
|
|
|
This device provides IOCTL interface to read standard ACPI
|
|
thermal relationship tables via ACPI methods _TRT and _ART.
|
|
These IOCTLs are defined in
|
|
drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
|
|
|
|
IOCTLs:
|
|
|
|
ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
|
|
|
|
ACPI_THERMAL_GET_ART_LEN: Get length of ART table
|
|
|
|
ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
|
|
|
|
ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
|
|
|
|
ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is
|
|
provided via argument to ioctl().
|
|
|
|
ACPI_THERMAL_GET_ART: Read binary ART table, length to read is
|
|
provided via argument to ioctl().
|
|
|
|
DPTF ACPI Sensor drivers
|
|
-------------------------
|
|
|
|
DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
|
|
|
|
|
|
DPTF ACPI Cooling drivers
|
|
--------------------------
|
|
|
|
DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
|
|
|
|
|
|
DPTF Processor thermal PCI Driver interface
|
|
--------------------------------------------
|
|
|
|
:file:`/sys/bus/pci/devices/0000\:00\:04.0/power_limits/`
|
|
|
|
Refer to Documentation/power/powercap/powercap.rst for powercap
|
|
ABI.
|
|
|
|
``power_limit_0_max_uw`` (RO)
|
|
Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
|
|
|
|
``power_limit_0_step_uw`` (RO)
|
|
Power limit increment/decrements for Intel RAPL constraint 0 power limit
|
|
|
|
``power_limit_0_min_uw`` (RO)
|
|
Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
|
|
|
|
``power_limit_0_tmin_us`` (RO)
|
|
Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
|
|
|
|
``power_limit_0_tmax_us`` (RO)
|
|
Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
|
|
|
|
``power_limit_1_max_uw`` (RO)
|
|
Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
|
|
|
|
``power_limit_1_step_uw`` (RO)
|
|
Power limit increment/decrements for Intel RAPL constraint 1 power limit
|
|
|
|
``power_limit_1_min_uw`` (RO)
|
|
Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
|
|
|
|
``power_limit_1_tmin_us`` (RO)
|
|
Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
|
|
|
|
``power_limit_1_tmax_us`` (RO)
|
|
Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
|
|
|
|
:file:`/sys/bus/pci/devices/0000\:00\:04.0/`
|
|
|
|
``tcc_offset_degree_celsius`` (RW)
|
|
TCC offset from the critical temperature where hardware will throttle
|
|
CPU.
|
|
|
|
:file:`/sys/bus/pci/devices/0000\:00\:04.0/workload_request`
|
|
|
|
``workload_available_types`` (RO)
|
|
Available workload types. User space can specify one of the workload type
|
|
it is currently executing via workload_type. For example: idle, bursty,
|
|
sustained etc.
|
|
|
|
``workload_type`` (RW)
|
|
User space can specify any one of the available workload type using
|
|
this interface.
|
|
|
|
DPTF Processor thermal RFIM interface
|
|
--------------------------------------------
|
|
|
|
RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator)
|
|
and DDR (Double Data Rate)frequencies to avoid RF interference with WiFi and 5G.
|
|
|
|
Switching voltage regulators (VR) generate radiated EMI or RFI at the
|
|
fundamental frequency and its harmonics. Some harmonics may interfere
|
|
with very sensitive wireless receivers such as Wi-Fi and cellular that
|
|
are integrated into host systems like notebook PCs. One of mitigation
|
|
methods is requesting SOC integrated VR (IVR) switching frequency to a
|
|
small % and shift away the switching noise harmonic interference from
|
|
radio channels. OEM or ODMs can use the driver to control SOC IVR
|
|
operation within the range where it does not impact IVR performance.
|
|
|
|
DRAM devices of DDR IO interface and their power plane can generate EMI
|
|
at the data rates. Similar to IVR control mechanism, Intel offers a
|
|
mechanism by which DDR data rates can be changed if several conditions
|
|
are met: there is strong RFI interference because of DDR; CPU power
|
|
management has no other restriction in changing DDR data rates;
|
|
PC ODMs enable this feature (real time DDR RFI Mitigation referred to as
|
|
DDR-RFIM) for Wi-Fi from BIOS.
|
|
|
|
|
|
FIVR attributes
|
|
|
|
:file:`/sys/bus/pci/devices/0000\:00\:04.0/fivr/`
|
|
|
|
``vco_ref_code_lo`` (RW)
|
|
The VCO reference code is an 11-bit field and controls the FIVR
|
|
switching frequency. This is the 3-bit LSB field.
|
|
|
|
``vco_ref_code_hi`` (RW)
|
|
The VCO reference code is an 11-bit field and controls the FIVR
|
|
switching frequency. This is the 8-bit MSB field.
|
|
|
|
``spread_spectrum_pct`` (RW)
|
|
Set the FIVR spread spectrum clocking percentage
|
|
|
|
``spread_spectrum_clk_enable`` (RW)
|
|
Enable/disable of the FIVR spread spectrum clocking feature
|
|
|
|
``rfi_vco_ref_code`` (RW)
|
|
This field is a read only status register which reflects the
|
|
current FIVR switching frequency
|
|
|
|
``fivr_fffc_rev`` (RW)
|
|
This field indicated the revision of the FIVR HW.
|
|
|
|
|
|
DVFS attributes
|
|
|
|
:file:`/sys/bus/pci/devices/0000\:00\:04.0/dvfs/`
|
|
|
|
``rfi_restriction_run_busy`` (RW)
|
|
Request the restriction of specific DDR data rate and set this
|
|
value 1. Self reset to 0 after operation.
|
|
|
|
``rfi_restriction_err_code`` (RW)
|
|
0 :Request is accepted, 1:Feature disabled,
|
|
2: the request restricts more points than it is allowed
|
|
|
|
``rfi_restriction_data_rate_Delta`` (RW)
|
|
Restricted DDR data rate for RFI protection: Lower Limit
|
|
|
|
``rfi_restriction_data_rate_Base`` (RW)
|
|
Restricted DDR data rate for RFI protection: Upper Limit
|
|
|
|
``ddr_data_rate_point_0`` (RO)
|
|
DDR data rate selection 1st point
|
|
|
|
``ddr_data_rate_point_1`` (RO)
|
|
DDR data rate selection 2nd point
|
|
|
|
``ddr_data_rate_point_2`` (RO)
|
|
DDR data rate selection 3rd point
|
|
|
|
``ddr_data_rate_point_3`` (RO)
|
|
DDR data rate selection 4th point
|
|
|
|
``rfi_disable (RW)``
|
|
Disable DDR rate change feature
|
|
|
|
DPTF Power supply and Battery Interface
|
|
----------------------------------------
|
|
|
|
Refer to Documentation/ABI/testing/sysfs-platform-dptf
|
|
|
|
DPTF Fan Control
|
|
----------------------------------------
|
|
|
|
Refer to Documentation/admin-guide/acpi/fan_performance_states.rst
|