linux-zen-server/tools/perf/pmu-events/arch/x86/ivybridge/memory.json

183 lines
6.5 KiB
JSON

[
{
"BriefDescription": "Counts the number of machine clears due to memory order conflicts.",
"EventCode": "0xC3",
"EventName": "MACHINE_CLEARS.MEMORY_ORDERING",
"SampleAfterValue": "100003",
"UMask": "0x2"
},
{
"BriefDescription": "Loads with latency value being above 128",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_128",
"MSRIndex": "0x3F6",
"MSRValue": "0x80",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 128.",
"SampleAfterValue": "1009",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 16",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_16",
"MSRIndex": "0x3F6",
"MSRValue": "0x10",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 16.",
"SampleAfterValue": "20011",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 256",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_256",
"MSRIndex": "0x3F6",
"MSRValue": "0x100",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 256.",
"SampleAfterValue": "503",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 32",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_32",
"MSRIndex": "0x3F6",
"MSRValue": "0x20",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 32.",
"SampleAfterValue": "100007",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 4",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_4",
"MSRIndex": "0x3F6",
"MSRValue": "0x4",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 4.",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 512",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_512",
"MSRIndex": "0x3F6",
"MSRValue": "0x200",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 512.",
"SampleAfterValue": "101",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 64",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_64",
"MSRIndex": "0x3F6",
"MSRValue": "0x40",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 64.",
"SampleAfterValue": "2003",
"UMask": "0x1"
},
{
"BriefDescription": "Loads with latency value being above 8",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.LOAD_LATENCY_GT_8",
"MSRIndex": "0x3F6",
"MSRValue": "0x8",
"PEBS": "2",
"PublicDescription": "Loads with latency value being above 8.",
"SampleAfterValue": "50021",
"UMask": "0x1"
},
{
"BriefDescription": "Sample stores and collect precise store operation via PEBS record. PMC3 only.",
"EventCode": "0xCD",
"EventName": "MEM_TRANS_RETIRED.PRECISE_STORE",
"PEBS": "2",
"SampleAfterValue": "2000003",
"UMask": "0x2"
},
{
"BriefDescription": "Speculative cache line split load uops dispatched to L1 cache",
"EventCode": "0x05",
"EventName": "MISALIGN_MEM_REF.LOADS",
"PublicDescription": "Speculative cache-line split load uops dispatched to L1D.",
"SampleAfterValue": "2000003",
"UMask": "0x1"
},
{
"BriefDescription": "Speculative cache line split STA uops dispatched to L1 cache",
"EventCode": "0x05",
"EventName": "MISALIGN_MEM_REF.STORES",
"PublicDescription": "Speculative cache-line split Store-address uops dispatched to L1D.",
"SampleAfterValue": "2000003",
"UMask": "0x2"
},
{
"BriefDescription": "Counts all demand & prefetch code reads that miss the LLC and the data returned from dram",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.ALL_CODE_RD.LLC_MISS.DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x300400244",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Counts all demand & prefetch data reads that miss the LLC and the data returned from dram",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.ALL_DATA_RD.LLC_MISS.DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x300400091",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Counts all data/code/rfo reads (demand & prefetch) that miss the LLC and the data returned from dram",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.ALL_READS.LLC_MISS.DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x3004003f7",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Counts LLC replacements",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.DATA_IN_SOCKET.LLC_MISS.LOCAL_DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x6004001b3",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Counts demand code reads that miss the LLC and the data returned from dram",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.DEMAND_CODE_RD.LLC_MISS.DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x300400004",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Counts demand data reads that miss the LLC and the data returned from dram",
"EventCode": "0xB7, 0xBB",
"EventName": "OFFCORE_RESPONSE.DEMAND_DATA_RD.LLC_MISS.DRAM",
"MSRIndex": "0x1a6,0x1a7",
"MSRValue": "0x300400001",
"SampleAfterValue": "100003",
"UMask": "0x1"
},
{
"BriefDescription": "Number of any page walk that had a miss in LLC.",
"EventCode": "0xBE",
"EventName": "PAGE_WALKS.LLC_MISS",
"SampleAfterValue": "100003",
"UMask": "0x1"
}
]