linux-zen-server/tools/perf/tests/shell/stat+json_output.sh

183 lines
4.1 KiB
Bash
Executable File

#!/bin/bash
# perf stat JSON output linter
# SPDX-License-Identifier: (LGPL-2.1 OR BSD-2-Clause)
# Checks various perf stat JSON output commands for the
# correct number of fields.
set -e
skip_test=0
pythonchecker=$(dirname $0)/lib/perf_json_output_lint.py
if [ "x$PYTHON" == "x" ]
then
if which python3 > /dev/null
then
PYTHON=python3
elif which python > /dev/null
then
PYTHON=python
else
echo Skipping test, python not detected please set environment variable PYTHON.
exit 2
fi
fi
# Return true if perf_event_paranoid is > $1 and not running as root.
function ParanoidAndNotRoot()
{
[ $(id -u) != 0 ] && [ $(cat /proc/sys/kernel/perf_event_paranoid) -gt $1 ]
}
check_no_args()
{
echo -n "Checking json output: no args "
perf stat -j true 2>&1 | $PYTHON $pythonchecker --no-args
echo "[Success]"
}
check_system_wide()
{
echo -n "Checking json output: system wide "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j -a true 2>&1 | $PYTHON $pythonchecker --system-wide
echo "[Success]"
}
check_system_wide_no_aggr()
{
echo -n "Checking json output: system wide "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
echo -n "Checking json output: system wide no aggregation "
perf stat -j -A -a --no-merge true 2>&1 | $PYTHON $pythonchecker --system-wide-no-aggr
echo "[Success]"
}
check_interval()
{
echo -n "Checking json output: interval "
perf stat -j -I 1000 true 2>&1 | $PYTHON $pythonchecker --interval
echo "[Success]"
}
check_event()
{
echo -n "Checking json output: event "
perf stat -j -e cpu-clock true 2>&1 | $PYTHON $pythonchecker --event
echo "[Success]"
}
check_per_core()
{
echo -n "Checking json output: per core "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j --per-core -a true 2>&1 | $PYTHON $pythonchecker --per-core
echo "[Success]"
}
check_per_thread()
{
echo -n "Checking json output: per thread "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j --per-thread -a true 2>&1 | $PYTHON $pythonchecker --per-thread
echo "[Success]"
}
check_per_die()
{
echo -n "Checking json output: per die "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j --per-die -a true 2>&1 | $PYTHON $pythonchecker --per-die
echo "[Success]"
}
check_per_node()
{
echo -n "Checking json output: per node "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j --per-node -a true 2>&1 | $PYTHON $pythonchecker --per-node
echo "[Success]"
}
check_per_socket()
{
echo -n "Checking json output: per socket "
if ParanoidAndNotRoot 0
then
echo "[Skip] paranoia and not root"
return
fi
perf stat -j --per-socket -a true 2>&1 | $PYTHON $pythonchecker --per-socket
echo "[Success]"
}
# The perf stat options for per-socket, per-core, per-die
# and -A ( no_aggr mode ) uses the info fetched from this
# directory: "/sys/devices/system/cpu/cpu*/topology". For
# example, socket value is fetched from "physical_package_id"
# file in topology directory.
# Reference: cpu__get_topology_int in util/cpumap.c
# If the platform doesn't expose topology information, values
# will be set to -1. For example, incase of pSeries platform
# of powerpc, value for "physical_package_id" is restricted
# and set to -1. Check here validates the socket-id read from
# topology file before proceeding further
FILE_LOC="/sys/devices/system/cpu/cpu*/topology/"
FILE_NAME="physical_package_id"
check_for_topology()
{
if ! ParanoidAndNotRoot 0
then
socket_file=`ls $FILE_LOC/$FILE_NAME | head -n 1`
[ -z $socket_file ] && return 0
socket_id=`cat $socket_file`
[ $socket_id == -1 ] && skip_test=1
return 0
fi
}
check_for_topology
check_no_args
check_system_wide
check_interval
check_event
check_per_thread
check_per_node
if [ $skip_test -ne 1 ]
then
check_system_wide_no_aggr
check_per_core
check_per_die
check_per_socket
else
echo "[Skip] Skipping tests for system_wide_no_aggr, per_core, per_die and per_socket since socket id exposed via topology is invalid"
fi
exit 0