494 lines
13 KiB
C
494 lines
13 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* arch/arm64/kernel/ftrace.c
|
|
*
|
|
* Copyright (C) 2013 Linaro Limited
|
|
* Author: AKASHI Takahiro <takahiro.akashi@linaro.org>
|
|
*/
|
|
|
|
#include <linux/ftrace.h>
|
|
#include <linux/module.h>
|
|
#include <linux/swab.h>
|
|
#include <linux/uaccess.h>
|
|
|
|
#include <asm/cacheflush.h>
|
|
#include <asm/debug-monitors.h>
|
|
#include <asm/ftrace.h>
|
|
#include <asm/insn.h>
|
|
#include <asm/patching.h>
|
|
|
|
#ifdef CONFIG_DYNAMIC_FTRACE_WITH_ARGS
|
|
struct fregs_offset {
|
|
const char *name;
|
|
int offset;
|
|
};
|
|
|
|
#define FREGS_OFFSET(n, field) \
|
|
{ \
|
|
.name = n, \
|
|
.offset = offsetof(struct ftrace_regs, field), \
|
|
}
|
|
|
|
static const struct fregs_offset fregs_offsets[] = {
|
|
FREGS_OFFSET("x0", regs[0]),
|
|
FREGS_OFFSET("x1", regs[1]),
|
|
FREGS_OFFSET("x2", regs[2]),
|
|
FREGS_OFFSET("x3", regs[3]),
|
|
FREGS_OFFSET("x4", regs[4]),
|
|
FREGS_OFFSET("x5", regs[5]),
|
|
FREGS_OFFSET("x6", regs[6]),
|
|
FREGS_OFFSET("x7", regs[7]),
|
|
FREGS_OFFSET("x8", regs[8]),
|
|
|
|
FREGS_OFFSET("x29", fp),
|
|
FREGS_OFFSET("x30", lr),
|
|
FREGS_OFFSET("lr", lr),
|
|
|
|
FREGS_OFFSET("sp", sp),
|
|
FREGS_OFFSET("pc", pc),
|
|
};
|
|
|
|
int ftrace_regs_query_register_offset(const char *name)
|
|
{
|
|
for (int i = 0; i < ARRAY_SIZE(fregs_offsets); i++) {
|
|
const struct fregs_offset *roff = &fregs_offsets[i];
|
|
if (!strcmp(roff->name, name))
|
|
return roff->offset;
|
|
}
|
|
|
|
return -EINVAL;
|
|
}
|
|
#endif
|
|
|
|
unsigned long ftrace_call_adjust(unsigned long addr)
|
|
{
|
|
/*
|
|
* When using mcount, addr is the address of the mcount call
|
|
* instruction, and no adjustment is necessary.
|
|
*/
|
|
if (!IS_ENABLED(CONFIG_DYNAMIC_FTRACE_WITH_ARGS))
|
|
return addr;
|
|
|
|
/*
|
|
* When using patchable-function-entry without pre-function NOPS, addr
|
|
* is the address of the first NOP after the function entry point.
|
|
*
|
|
* The compiler has either generated:
|
|
*
|
|
* addr+00: func: NOP // To be patched to MOV X9, LR
|
|
* addr+04: NOP // To be patched to BL <caller>
|
|
*
|
|
* Or:
|
|
*
|
|
* addr-04: BTI C
|
|
* addr+00: func: NOP // To be patched to MOV X9, LR
|
|
* addr+04: NOP // To be patched to BL <caller>
|
|
*
|
|
* We must adjust addr to the address of the NOP which will be patched
|
|
* to `BL <caller>`, which is at `addr + 4` bytes in either case.
|
|
*
|
|
*/
|
|
if (!IS_ENABLED(CONFIG_DYNAMIC_FTRACE_WITH_CALL_OPS))
|
|
return addr + AARCH64_INSN_SIZE;
|
|
|
|
/*
|
|
* When using patchable-function-entry with pre-function NOPs, addr is
|
|
* the address of the first pre-function NOP.
|
|
*
|
|
* Starting from an 8-byte aligned base, the compiler has either
|
|
* generated:
|
|
*
|
|
* addr+00: NOP // Literal (first 32 bits)
|
|
* addr+04: NOP // Literal (last 32 bits)
|
|
* addr+08: func: NOP // To be patched to MOV X9, LR
|
|
* addr+12: NOP // To be patched to BL <caller>
|
|
*
|
|
* Or:
|
|
*
|
|
* addr+00: NOP // Literal (first 32 bits)
|
|
* addr+04: NOP // Literal (last 32 bits)
|
|
* addr+08: func: BTI C
|
|
* addr+12: NOP // To be patched to MOV X9, LR
|
|
* addr+16: NOP // To be patched to BL <caller>
|
|
*
|
|
* We must adjust addr to the address of the NOP which will be patched
|
|
* to `BL <caller>`, which is at either addr+12 or addr+16 depending on
|
|
* whether there is a BTI.
|
|
*/
|
|
|
|
if (!IS_ALIGNED(addr, sizeof(unsigned long))) {
|
|
WARN_RATELIMIT(1, "Misaligned patch-site %pS\n",
|
|
(void *)(addr + 8));
|
|
return 0;
|
|
}
|
|
|
|
/* Skip the NOPs placed before the function entry point */
|
|
addr += 2 * AARCH64_INSN_SIZE;
|
|
|
|
/* Skip any BTI */
|
|
if (IS_ENABLED(CONFIG_ARM64_BTI_KERNEL)) {
|
|
u32 insn = le32_to_cpu(*(__le32 *)addr);
|
|
|
|
if (aarch64_insn_is_bti(insn)) {
|
|
addr += AARCH64_INSN_SIZE;
|
|
} else if (insn != aarch64_insn_gen_nop()) {
|
|
WARN_RATELIMIT(1, "unexpected insn in patch-site %pS: 0x%08x\n",
|
|
(void *)addr, insn);
|
|
}
|
|
}
|
|
|
|
/* Skip the first NOP after function entry */
|
|
addr += AARCH64_INSN_SIZE;
|
|
|
|
return addr;
|
|
}
|
|
|
|
/*
|
|
* Replace a single instruction, which may be a branch or NOP.
|
|
* If @validate == true, a replaced instruction is checked against 'old'.
|
|
*/
|
|
static int ftrace_modify_code(unsigned long pc, u32 old, u32 new,
|
|
bool validate)
|
|
{
|
|
u32 replaced;
|
|
|
|
/*
|
|
* Note:
|
|
* We are paranoid about modifying text, as if a bug were to happen, it
|
|
* could cause us to read or write to someplace that could cause harm.
|
|
* Carefully read and modify the code with aarch64_insn_*() which uses
|
|
* probe_kernel_*(), and make sure what we read is what we expected it
|
|
* to be before modifying it.
|
|
*/
|
|
if (validate) {
|
|
if (aarch64_insn_read((void *)pc, &replaced))
|
|
return -EFAULT;
|
|
|
|
if (replaced != old)
|
|
return -EINVAL;
|
|
}
|
|
if (aarch64_insn_patch_text_nosync((void *)pc, new))
|
|
return -EPERM;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Replace tracer function in ftrace_caller()
|
|
*/
|
|
int ftrace_update_ftrace_func(ftrace_func_t func)
|
|
{
|
|
unsigned long pc;
|
|
u32 new;
|
|
|
|
/*
|
|
* When using CALL_OPS, the function to call is associated with the
|
|
* call site, and we don't have a global function pointer to update.
|
|
*/
|
|
if (IS_ENABLED(CONFIG_DYNAMIC_FTRACE_WITH_CALL_OPS))
|
|
return 0;
|
|
|
|
pc = (unsigned long)ftrace_call;
|
|
new = aarch64_insn_gen_branch_imm(pc, (unsigned long)func,
|
|
AARCH64_INSN_BRANCH_LINK);
|
|
|
|
return ftrace_modify_code(pc, 0, new, false);
|
|
}
|
|
|
|
static struct plt_entry *get_ftrace_plt(struct module *mod, unsigned long addr)
|
|
{
|
|
#ifdef CONFIG_ARM64_MODULE_PLTS
|
|
struct plt_entry *plt = mod->arch.ftrace_trampolines;
|
|
|
|
if (addr == FTRACE_ADDR)
|
|
return &plt[FTRACE_PLT_IDX];
|
|
#endif
|
|
return NULL;
|
|
}
|
|
|
|
/*
|
|
* Find the address the callsite must branch to in order to reach '*addr'.
|
|
*
|
|
* Due to the limited range of 'BL' instructions, modules may be placed too far
|
|
* away to branch directly and must use a PLT.
|
|
*
|
|
* Returns true when '*addr' contains a reachable target address, or has been
|
|
* modified to contain a PLT address. Returns false otherwise.
|
|
*/
|
|
static bool ftrace_find_callable_addr(struct dyn_ftrace *rec,
|
|
struct module *mod,
|
|
unsigned long *addr)
|
|
{
|
|
unsigned long pc = rec->ip;
|
|
long offset = (long)*addr - (long)pc;
|
|
struct plt_entry *plt;
|
|
|
|
/*
|
|
* When the target is within range of the 'BL' instruction, use 'addr'
|
|
* as-is and branch to that directly.
|
|
*/
|
|
if (offset >= -SZ_128M && offset < SZ_128M)
|
|
return true;
|
|
|
|
/*
|
|
* When the target is outside of the range of a 'BL' instruction, we
|
|
* must use a PLT to reach it. We can only place PLTs for modules, and
|
|
* only when module PLT support is built-in.
|
|
*/
|
|
if (!IS_ENABLED(CONFIG_ARM64_MODULE_PLTS))
|
|
return false;
|
|
|
|
/*
|
|
* 'mod' is only set at module load time, but if we end up
|
|
* dealing with an out-of-range condition, we can assume it
|
|
* is due to a module being loaded far away from the kernel.
|
|
*
|
|
* NOTE: __module_text_address() must be called with preemption
|
|
* disabled, but we can rely on ftrace_lock to ensure that 'mod'
|
|
* retains its validity throughout the remainder of this code.
|
|
*/
|
|
if (!mod) {
|
|
preempt_disable();
|
|
mod = __module_text_address(pc);
|
|
preempt_enable();
|
|
}
|
|
|
|
if (WARN_ON(!mod))
|
|
return false;
|
|
|
|
plt = get_ftrace_plt(mod, *addr);
|
|
if (!plt) {
|
|
pr_err("ftrace: no module PLT for %ps\n", (void *)*addr);
|
|
return false;
|
|
}
|
|
|
|
*addr = (unsigned long)plt;
|
|
return true;
|
|
}
|
|
|
|
#ifdef CONFIG_DYNAMIC_FTRACE_WITH_CALL_OPS
|
|
static const struct ftrace_ops *arm64_rec_get_ops(struct dyn_ftrace *rec)
|
|
{
|
|
const struct ftrace_ops *ops = NULL;
|
|
|
|
if (rec->flags & FTRACE_FL_CALL_OPS_EN) {
|
|
ops = ftrace_find_unique_ops(rec);
|
|
WARN_ON_ONCE(!ops);
|
|
}
|
|
|
|
if (!ops)
|
|
ops = &ftrace_list_ops;
|
|
|
|
return ops;
|
|
}
|
|
|
|
static int ftrace_rec_set_ops(const struct dyn_ftrace *rec,
|
|
const struct ftrace_ops *ops)
|
|
{
|
|
unsigned long literal = ALIGN_DOWN(rec->ip - 12, 8);
|
|
return aarch64_insn_write_literal_u64((void *)literal,
|
|
(unsigned long)ops);
|
|
}
|
|
|
|
static int ftrace_rec_set_nop_ops(struct dyn_ftrace *rec)
|
|
{
|
|
return ftrace_rec_set_ops(rec, &ftrace_nop_ops);
|
|
}
|
|
|
|
static int ftrace_rec_update_ops(struct dyn_ftrace *rec)
|
|
{
|
|
return ftrace_rec_set_ops(rec, arm64_rec_get_ops(rec));
|
|
}
|
|
#else
|
|
static int ftrace_rec_set_nop_ops(struct dyn_ftrace *rec) { return 0; }
|
|
static int ftrace_rec_update_ops(struct dyn_ftrace *rec) { return 0; }
|
|
#endif
|
|
|
|
/*
|
|
* Turn on the call to ftrace_caller() in instrumented function
|
|
*/
|
|
int ftrace_make_call(struct dyn_ftrace *rec, unsigned long addr)
|
|
{
|
|
unsigned long pc = rec->ip;
|
|
u32 old, new;
|
|
int ret;
|
|
|
|
ret = ftrace_rec_update_ops(rec);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (!ftrace_find_callable_addr(rec, NULL, &addr))
|
|
return -EINVAL;
|
|
|
|
old = aarch64_insn_gen_nop();
|
|
new = aarch64_insn_gen_branch_imm(pc, addr, AARCH64_INSN_BRANCH_LINK);
|
|
|
|
return ftrace_modify_code(pc, old, new, true);
|
|
}
|
|
|
|
#ifdef CONFIG_DYNAMIC_FTRACE_WITH_CALL_OPS
|
|
int ftrace_modify_call(struct dyn_ftrace *rec, unsigned long old_addr,
|
|
unsigned long addr)
|
|
{
|
|
if (WARN_ON_ONCE(old_addr != (unsigned long)ftrace_caller))
|
|
return -EINVAL;
|
|
if (WARN_ON_ONCE(addr != (unsigned long)ftrace_caller))
|
|
return -EINVAL;
|
|
|
|
return ftrace_rec_update_ops(rec);
|
|
}
|
|
#endif
|
|
|
|
#ifdef CONFIG_DYNAMIC_FTRACE_WITH_ARGS
|
|
/*
|
|
* The compiler has inserted two NOPs before the regular function prologue.
|
|
* All instrumented functions follow the AAPCS, so x0-x8 and x19-x30 are live,
|
|
* and x9-x18 are free for our use.
|
|
*
|
|
* At runtime we want to be able to swing a single NOP <-> BL to enable or
|
|
* disable the ftrace call. The BL requires us to save the original LR value,
|
|
* so here we insert a <MOV X9, LR> over the first NOP so the instructions
|
|
* before the regular prologue are:
|
|
*
|
|
* | Compiled | Disabled | Enabled |
|
|
* +----------+------------+------------+
|
|
* | NOP | MOV X9, LR | MOV X9, LR |
|
|
* | NOP | NOP | BL <entry> |
|
|
*
|
|
* The LR value will be recovered by ftrace_caller, and restored into LR
|
|
* before returning to the regular function prologue. When a function is not
|
|
* being traced, the MOV is not harmful given x9 is not live per the AAPCS.
|
|
*
|
|
* Note: ftrace_process_locs() has pre-adjusted rec->ip to be the address of
|
|
* the BL.
|
|
*/
|
|
int ftrace_init_nop(struct module *mod, struct dyn_ftrace *rec)
|
|
{
|
|
unsigned long pc = rec->ip - AARCH64_INSN_SIZE;
|
|
u32 old, new;
|
|
int ret;
|
|
|
|
ret = ftrace_rec_set_nop_ops(rec);
|
|
if (ret)
|
|
return ret;
|
|
|
|
old = aarch64_insn_gen_nop();
|
|
new = aarch64_insn_gen_move_reg(AARCH64_INSN_REG_9,
|
|
AARCH64_INSN_REG_LR,
|
|
AARCH64_INSN_VARIANT_64BIT);
|
|
return ftrace_modify_code(pc, old, new, true);
|
|
}
|
|
#endif
|
|
|
|
/*
|
|
* Turn off the call to ftrace_caller() in instrumented function
|
|
*/
|
|
int ftrace_make_nop(struct module *mod, struct dyn_ftrace *rec,
|
|
unsigned long addr)
|
|
{
|
|
unsigned long pc = rec->ip;
|
|
u32 old = 0, new;
|
|
int ret;
|
|
|
|
new = aarch64_insn_gen_nop();
|
|
|
|
ret = ftrace_rec_set_nop_ops(rec);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/*
|
|
* When using mcount, callsites in modules may have been initalized to
|
|
* call an arbitrary module PLT (which redirects to the _mcount stub)
|
|
* rather than the ftrace PLT we'll use at runtime (which redirects to
|
|
* the ftrace trampoline). We can ignore the old PLT when initializing
|
|
* the callsite.
|
|
*
|
|
* Note: 'mod' is only set at module load time.
|
|
*/
|
|
if (!IS_ENABLED(CONFIG_DYNAMIC_FTRACE_WITH_ARGS) &&
|
|
IS_ENABLED(CONFIG_ARM64_MODULE_PLTS) && mod) {
|
|
return aarch64_insn_patch_text_nosync((void *)pc, new);
|
|
}
|
|
|
|
if (!ftrace_find_callable_addr(rec, mod, &addr))
|
|
return -EINVAL;
|
|
|
|
old = aarch64_insn_gen_branch_imm(pc, addr, AARCH64_INSN_BRANCH_LINK);
|
|
|
|
return ftrace_modify_code(pc, old, new, true);
|
|
}
|
|
|
|
void arch_ftrace_update_code(int command)
|
|
{
|
|
command |= FTRACE_MAY_SLEEP;
|
|
ftrace_modify_all_code(command);
|
|
}
|
|
|
|
#ifdef CONFIG_FUNCTION_GRAPH_TRACER
|
|
/*
|
|
* function_graph tracer expects ftrace_return_to_handler() to be called
|
|
* on the way back to parent. For this purpose, this function is called
|
|
* in _mcount() or ftrace_caller() to replace return address (*parent) on
|
|
* the call stack to return_to_handler.
|
|
*/
|
|
void prepare_ftrace_return(unsigned long self_addr, unsigned long *parent,
|
|
unsigned long frame_pointer)
|
|
{
|
|
unsigned long return_hooker = (unsigned long)&return_to_handler;
|
|
unsigned long old;
|
|
|
|
if (unlikely(atomic_read(¤t->tracing_graph_pause)))
|
|
return;
|
|
|
|
/*
|
|
* Note:
|
|
* No protection against faulting at *parent, which may be seen
|
|
* on other archs. It's unlikely on AArch64.
|
|
*/
|
|
old = *parent;
|
|
|
|
if (!function_graph_enter(old, self_addr, frame_pointer,
|
|
(void *)frame_pointer)) {
|
|
*parent = return_hooker;
|
|
}
|
|
}
|
|
|
|
#ifdef CONFIG_DYNAMIC_FTRACE_WITH_ARGS
|
|
void ftrace_graph_func(unsigned long ip, unsigned long parent_ip,
|
|
struct ftrace_ops *op, struct ftrace_regs *fregs)
|
|
{
|
|
prepare_ftrace_return(ip, &fregs->lr, fregs->fp);
|
|
}
|
|
#else
|
|
/*
|
|
* Turn on/off the call to ftrace_graph_caller() in ftrace_caller()
|
|
* depending on @enable.
|
|
*/
|
|
static int ftrace_modify_graph_caller(bool enable)
|
|
{
|
|
unsigned long pc = (unsigned long)&ftrace_graph_call;
|
|
u32 branch, nop;
|
|
|
|
branch = aarch64_insn_gen_branch_imm(pc,
|
|
(unsigned long)ftrace_graph_caller,
|
|
AARCH64_INSN_BRANCH_NOLINK);
|
|
nop = aarch64_insn_gen_nop();
|
|
|
|
if (enable)
|
|
return ftrace_modify_code(pc, nop, branch, true);
|
|
else
|
|
return ftrace_modify_code(pc, branch, nop, true);
|
|
}
|
|
|
|
int ftrace_enable_ftrace_graph_caller(void)
|
|
{
|
|
return ftrace_modify_graph_caller(true);
|
|
}
|
|
|
|
int ftrace_disable_ftrace_graph_caller(void)
|
|
{
|
|
return ftrace_modify_graph_caller(false);
|
|
}
|
|
#endif /* CONFIG_DYNAMIC_FTRACE_WITH_ARGS */
|
|
#endif /* CONFIG_FUNCTION_GRAPH_TRACER */
|